What changes
Unit 09, object 0A69: bits 0.3, 0.6, 2.0, 2.2, 2.5 = 1, bit 2.4 = 0. Hold “unlock” and the windows go down, hold “lock” and they go up.
Details
Setting of the newer MQB body control module; the individual bits are not decoded — the preset sets the whole group. This is holding the key fob buttons; closing the windows by touching the door handle with keyless access is a different setting with no known map. Window anti-pinch works as usual. a3c first checks that the unit 09 long coding is empty, as on the newer module. Unit 09 on MQB Evo is SFD-protected — a token for unit 09 is needed. Roll back by writing the object backup from history.