What changes
Module 09: object 50C4, byte 13, bit 5 = 1 (0D03, byte 1, bit 1 on a coded module). Open the boot — the interior lights come on.
Details
The interior lamps come on when the boot is opened, as when a door opens. The bits are not yet confirmed by a write on an A3 8V. The map comes in two variants — object 50C4 (module without long coding) or 0D03 (module with a filled long coding); Odyx uses whichever object the module has. Access code 31347. Rollback: write the object backup from the history.