What changes
Module 09: object 0A58, byte 3, bit 5 = 1 (0D02, byte 0, bit 5 on a coded module). While the parking brake is applied the DRL stay off.
Details
The DRL go off while the parking brake is applied. Switching DRL off with the engine running is illegal in some countries. The map comes in two variants — object 0A58 (module without long coding) or 0D02 (module with a filled long coding); Odyx uses whichever object the module has. Access code 31347. Rollback: write the object backup from the history.