What changes
Module 19 (gateway): long coding, byte 8, bit 4 = 1. The gateway passes the selected driving mode to the cluster for display.
Details
Kodiaq I (NS). Needs factory driving mode selection. This command belongs to gateway 19, not to cluster 17. The map has not been confirmed by a write on a car; Odyx reads the coding first and shows the changes. To undo, use the write history.