What changes
Module 09: object 0A5E, byte 0, bits 1–2 = 11, bit 4 = 1 (0D00, bits 1–2 and bit 7 on a coded module). A light tap of the stalk gives 5 flashes.
Details
Tiguan II AD1. MQB map; before the change Odyx reads the available objects. Not yet confirmed by a write on a Tiguan. Later modules need the bonnet open. To undo, use the write history.
Other options
This is one option of the “Comfort turn signal” setting: only one can be active.