Multimedia

AdBlue level in the MMI

The AdBlue range is shown in the MMI, not only as a cluster warning.

Odyx Pro↻ MMI restarts

What changes

Unit 5F, AdBlue menu item: MIB3 — 0B1B byte 53, bits 7 and 5; MIB2 — 0B3C byte 53, bits 0 and 2. The MMI gets a screen with the AdBlue range.

Details

Diesels with AdBlue only. Two menu flags are enabled: 'show' and 'show while driving'. MIB2 and MIB3 share the menu list, but the bit order in the byte is reversed — a3c picks the variant by the object the unit knows. For MIB2 the bit order is derived from neighbouring menu items and has not been verified by a write yet. If the unit is SFD-protected, a3c warns before writing. The MMI restarts after writing. To turn off, set the same bits to 0.

Odyx · Owner’s manualHow to use

How to enable it in Odyx

  1. Plug an ELM327 Bluetooth LE adapter into the OBD port (on a Mac also Wi‑Fi, USB or DoIP).
  2. Odyx scans the units, recognises the car and shows what is on and what can be enabled.
  3. Open the feature card: before / after / how to check, and the change plan.
  4. Confirm the write. A backup is made automatically; put it back from the logbook any time.
☑ Engine off
☑ Ignition on
☑ Voltage 12 V or more
☑ Car off the road

Safety rules →